Difference between revisions of "Preprocess raw reads (analysis)"

From BioUML platform
Jump to: navigation, search
m (Protected "Preprocess raw reads (analysis)": Autogenerated page (‎[edit=sysop] (indefinite)))
(Provider information added)
Line 1: Line 1:
 +
;Analysis title
 +
:Preprocess raw reads
 +
;Provider
 +
:[[Institute of Systems Biology]]
 +
 +
==== Description ====
 
Remove reads not satisfying simple quality tests, removes adapters, trims low quality bases from read ends
 
Remove reads not satisfying simple quality tests, removes adapters, trims low quality bases from read ends
  

Revision as of 15:40, 18 April 2013

Analysis title
Preprocess raw reads
Provider
Institute of Systems Biology

Description

Remove reads not satisfying simple quality tests, removes adapters, trims low quality bases from read ends

Parameters:

  • Library type – Type of DNA library
  • Input type – Type of input files
  • Input fastq file – Input fastq file
  • Input csfasta file – Input csfasta file
  • Input qual file – Input qual file
  • Input first fastq file – Input first fastq file
  • Input second fastq file – Input second fastq file
  • Input first csfasta file – Input first csfasta file
  • Input first qual file – Input first qual file
  • Input second csfasta file – Input second csfasta file
  • Input second qual file – Input second qual file
  • Quality encoding – This specifies how phred quality values are encoded in the FASTQ file. In most of the cases system detects this value automatically. You may change it manually if auto-detection worked incorrectly.
  • Processors – Read processors to apply
    • Cut adapters – Cut adapter sequences
      • Enabled – Wheter processor is enabled
      • Minimal match – Minimal lenght of match between read and adapter
      • Error rate – Fraction of mismatches between read and adapter
      • Adapters – Adapters
    • Trim low quality – Trim low quality bases from the 3' end of reads
      • Enabled – Wheter processor is enabled
      • Phred quality threshold – Phred quality threshold
    • Remove too short – Remove reads shorter then specified length
      • Enabled – Wheter processor is enabled
      • Minimal read length – Reads shorter than given length will be excluded
    • Remove low quality reads – Remove low quality reads
      • Enabled – Wheter processor is enabled
      • Minimal phred quality – Read phred quality cutoff
      • Maximal % of low-quality bp – Reads where more bp's have quality below the cutoff will be excluded
  • Output fastq file – Output fastq file
  • Output csfasta file – Output csfasta file
  • Output qual file – Output qual file
  • Output first fastq file – Output first fastq file
  • Output second fastq file – Output second fastq file
  • Output first csfasta file – Output first csfasta file
  • Output first qual file – Output first qual file
  • Output second csfasta file – Output second csfasta file
  • Output second qual file – Output second qual file
Personal tools
Namespaces

Variants
Actions
BioUML platform
Community
Modelling
Analysis & Workflows
Collaborative research
Development
Virtual biology
Wiki
Toolbox